SPECIFICATION
MODEL LPV-60-5 LPV-60-12 LPV-60-15 LPV-60-24 LPV-60-36 LPV-60-48
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
LINEREGULATION
LOADREGULATION
SETUP,RISETIME Note.6
HOLDUP TIME(Typ.)
VOLTAGERANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
ACCURRENT (Typ.)
INPUT
INRUSHCURRENT(max.)
LEAKAGECURRENT
SAFETY STANDARDS
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
5V 12V 15V 24V 36V 48V
8A 5A 4A 2.5A 1.67A 1.25A
0~8A 0~5A 0~4A 0~2.5A 0~1.67A 0~1.25A
40W 60W 60W 60W 60W 60W
80mVp-p 120mVp-p 120mVp-p 150mVp-p 150mVp-p 150mVp-p
8.0%
1.0%
6.0%
90~264VAC 127~370VDC
47~63Hz
76% 83%
2.0%
5.0%
83% 86% 86% 86%
5.75~6.75V 13.8~16.2V 17.25~20.25V 27.6~32.4V 41.4~48.6V 55.2~64.8V
1.2A/115VAC1A/230VAC
0.25mA /240VAC
110~150%ratedoutputpower
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
CompliancetoEN55022(CISPR22)ClassB, EN61000-3-2Class A,EN61000-3-3
CompliancetoEN61000-4-2,3,4,5,6,8,11,EN55024,lightindustrylevel,criteria A
-30~+70 (Referto"DeratingCurve")
20~90%RH non-condensing
-40~+80 ,10~95%RH
0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,periodfor 60min.eachalongX, Y,Zaxes
732Khrsmin.MIL-HDBK-217F(25 )
162.5*42.5*32mm(L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
8. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
0.4Kg;32pcs/13.8Kg/0.56CUFT
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
60WSingleOutputSwitchingPowerSupply
Features :
LPV-60
ser i e s
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVAC
UL879(exceptforLPV-60-5),UL1310(exceptforLPV-60-5),CSA C22.2No.207-M89(exceptforLPV-60-5,LPV-60-48),
CAN/CSA C22.2No.223-M91(exceptforLPV-60-5,LPV-60-48),IP67approved;designreferto TUVEN60950-1
I/P-O/P:>100MOhms/500VDC/25 /70%RH
FileName:LPV-60-SPEC 2012-12-26
Constant voltage design
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Fully encapsulated with IP67 level
Class 2 power unit
ass LPS
Suitable for LED lighting and moving sign applications
100% full load burn-in test
Low cost, high reliability
2 years warranty
(Note.8)
Fully isolated plastic case
Class power unit, no FG
P
(Note.7)
500ms,20ms/230VAC5 atfullload ;00ms,20ms/115VAC (for5~36V)500ms,30ms/230VAC500ms,30ms/115VACatfullload(for48V)
50ms/230VAC16ms/115VACatfullload
( for 48V only) ( except for 5V,48V )
EMCIMMUNITY
EMCEMISSION
IP67
LPS
COLDSTART 60A(t =525smeasuredat50%I )at230VACwidth peak
Seitenansicht 0