Table 6.1: Failure Messages On Front Panel
10 0
10 0
10 0
10 0
0
0
0
0
LOA D
L O A D
L O A D
L O A D
(>1875W)
Output
Overload
Output
Overload
(1500W~1750W)
Failure
Message
Output
Overload
Over
Temperature
(1750W~1875W)
LED
Indicator
LED
Indicator
AC Output
Short Circuit
Failure
Message
Abnormal
AC Output
Voltage
Abnormal
Battery
Voltage
6.2 Output Protection
(A)Bypass Mode: Uses "No Fuse Breaker" as automatic over current
(B)Inverter Mode: Under the "Inverter Mode", if any abnormal situation
(1)Over Temperature Protection: When the internal temperature is higher
(2)AC Output Abnormal Protection: When the AC output voltage of the
(3)AC Output Short Circuit Protection: When a short circuit situation
(4)Battery Voltage Abnormal Protection: When the battery voltage is too
(5)Output Overload Protection: When output is overloaded between 1500W
protection. When over current occurs, the button of the circuit breaker on
occurs, the front panel will send out failure messages through the "Load
than the limit value, the "Over Temperature Protection" will be activated.
inverter is too high or too low, the unit will turn off and should be restarted
occurs at the output side of the inverter or the load increase greatly in a
high or too low, this protection will be activated. The inverter will auto-
~ 1750W, the inverter can continuously provide power for 3 minutes. After
that, if the overload condition is not removed, the overload protection will
be activated. When the load is higher than 1875W, the overload protection
will activate instantly. For these overload protections, once activated, you
should reset the unit.
recover once the battery voltage go back to a safe level and users do not
need to restart it.
short period of time, the unit will turn off and should be restarted again.
again.
The unit will automatically turn off and should be restarted again.
Meter" (Please refer to Table 6.1).
the front panel will pop up and the inverter will shut down. At this time,
users should remove the loads, restart the inverter and press down on the
button of the circuit breaker and the AC output can now be provided
normally.