Mean Well CLG-100-48 Datenblatt

Stöbern Sie online oder laden Sie Datenblatt nach Netzteile Mean Well CLG-100-48 herunter. MEAN WELL CLG-100-48 power supply unit Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 3
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
SPECIFICATION
MODEL CLG-100-12 CLG-100-15 CLG-100-20 CLG-100-24 CLG-100-27 CLG-100-36 CLG-100-48
DC VOLTAGE
RATED CURRENT
Note.5
RATED POWER Note.5
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(max.)
LEAKAGE CURRENT
SAFETY STANDARDS
Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT (Typ.)
OVER VOLTAGE
OVER TEMPERATURE
12V
9 ~ 12V
15V
11.25 ~ 15V
20V
15 ~ 20V
24V
18 ~ 24V
27V
20.25 ~ 27V
36V
27 ~ 36V
48V
36 ~ 48V
5A 5A 4.8A 4A
3.55A
2.65A 2A
60W 75W 96W 96W 95.85W 95.4W 96W
150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 150mVp-p 200mVp-p
±3.0% ±3.0% ±3.0% ±3.0% ±3.0% ±2.0% ±2.0%
Fixed. Can be modified between 0% ~ -15% rated output voltage
Fixed. Can be modified between 3% ~ -25% rated output current
±1.0%
±2.0%
1200ms, 80ms / 230VAC 1200ms, 80ms / 115VAC at full load
60ms / 230VAC 30ms / 115VAC at full load
90 ~ 295VAC 127 ~ 417VDC
47 ~ 63Hz
PF>0.95/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
83% 85% 88.5% 88.5% 88% 88% 88.5%
13 ~ 16V 16.5 ~ 20V 22 ~ 27V 27 ~ 34V 30 ~ 36V 39 ~ 48V 52 ~ 64V
12V:0.8A/115VAC 0.4A/230VAC 0.3A/277VAC 15V:0.9A/115VAC 0.45A/230VAC 0.35A/277VAC
20V ~ 48V:1.1A/115VAC 0.55A/230VAC 0.45A/277VAC
<0.75mA / 240VAC
95 ~ 102%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL879, UL8750, UL1310, TUV EN61347-1, EN61347-2-13 independent, CAN/CSA C22.2 No. 223-M91(except for 48V),
CSA C22.2 No. 250.0-08(except for 48V), CSA C22.2 No. 207-M89(except for 48V), TUV EN60950-1, IP67, J61347-1, J61347-2-13 approved
301K hrs min. MIL-HDBK-217F (25 )
222.2*68*38.8mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. This is the maximum possible output current and power, over load protection may be activated slightly below this level to comply with the requirement
of UL1310 class 2.
6. 3 years warranty is guaranteed for operating ambient temperature no higher than 68 .
7. lease refer to "DRIVING METHODS OF LED MODULE".P
8. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
1.0Kg; 12pcs/13Kg/0.58CUFT
Protection type : Shut down and latch off o/p voltage, re-power on to recover
100W Single Output Switching Power Supply
Universal AC input / Full range (up to 295VAC)
Built-in active PFC function
High efficiency up to 88.5%
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
IP67 design for indoor or outdoor installations
Class 2 power unit
Pass LPS
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty (Note.6)
Features :
CLG-100 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
Shut down o/p voltage, re-power on to recover
CONSTANT CURRENT REGION
Note.7
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
File Name:CLG-100-SPEC 2013-11-27
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C ( 75% load) ; EN61000-3-3
EMC IMMUNITY
EMC EMISSION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
COLD START 40A(t =1030 s measured at 50% I ) at 230VAC
width peak
μ
IP67
..
( for 48V only) ( except for 48V )
FMM
110
LPS
SELV
Seitenansicht 0
1 2 3

Inhaltsverzeichnis

Seite 1 - CLG-100 series

SPECIFICATIONMODEL CLG-100-12 CLG-100-15 CLG-100-20 CLG-100-24 CLG-100-27 CLG-100-36 CLG-100-48DC VOLTAGERATED CURRENTNote.5RATED POWER Note.5OUTPUTVO

Seite 2

Mechanical SpecificationFile Name:CLG-100-SPEC 2013-11-27Case No. 954A Unit:mmFosc : 100KHzDerating Curve Static CharacteristicsLOAD (%)-30 -25 -10

Seite 3

60646872768084889210% 20% 30% 40% 50% 60% 70% 80% 90% 100%277Vac230Vac115Vac0.780.800.820.840.860.880.900.920.940.960.981.0050% 60% 70% 80% 90% 100%27

Kommentare zu diesen Handbüchern

Keine Kommentare